MIL-G-85742/5(AS)
3.2.1.7 G-Bias/Nav Gain (GB/NG) input disable voltage. Prior to PCO,
the GB/NG input disable voltage shall be greater than 12 V.
3.2.1.8 Unregulated +6 V. The +6 V unregulated telemetry voltage shall
be 6 + 1 V.
3.2.1.9 Regulator output. The regulator output current shall actuate
the relay of Figure 1 at an alternator frequency of 6100 ± 400 Hz.
3.2.1.10 Launch lock voltage. The launch lock voltage shall be greater
than or equal to 12 volts direct current when driving a 29.5 ± 2.5
ohm load. The ac ripple shall be less than 2 volts peak-to-peak.
3.2.1.11 Contact destructs No less than 4 seconds after PCO, the energy
within the contact destruct fire pulse shall be not less than 33,000 ergs.
3.2.2 Physical characteristics. Physical characteristics shall be in
accordance with Drawings 1466AS12U2 and 1466AS1220.
4.
QUALITY ASSURANCE PROVISION
4.1 General. Each servo section shall meet the requirements of 3.2 when
inspected and tested as specified on Drawings 1466ASJ202 and 1466AS1220,
and the following paragraphs. Failure to meet any of the requirements
shall be cause for rejection of the servo section.
4.1.1 Test environment. Unless otherwise specified, all tests and
inspections shall be conducted under the following environmental
conditions:
Temperature (ambient):
23 ± 5 degrees Celsius (°C).
a.
Elevation of test facility.
b.
Altitude:
95 percent or less.
Relative humidity:
c.
4.1.2 Test equipment accuracy. Unless otherwise specified test equip-
ment accuracy shall be as specified in MIL-G-85742.
4.2 Quality conformance inspections
4.2.1 Unit test. The assembly shall be subjected to a unit test in
order to establish conformance to the requirements specified herein.
4.2.2 Test methods. Details of methods and procedures shall be in
accordance with the Government approved test procedure. The following test
shall be performed with a simulated power supply assembly (Drawing
1466AS1302) connected, closing the feedback loop.